Blue essence salt chlorine generator owner's manual . The LCD on the Aqua Rite will read Cold when the water temperature is below 50 F. If your water is not below that threshold, you can check the cell. Chlorine generator for inground swimming pools up to 25,000 gallons, USE ONLY HAYWARD GENUINE REPLACEMENT PARTS, Salt & swim chemistry quick start guide (2 pages), Salt & swim installation quick start guide (2 pages), Hayward salt swim 3c pro swimming pool salt chlorination system (1 page), Chlorine generator for inground swimming pools up to 30,000 gallons (25 pages), Salt & swim 3c installation quick start guide (2 pages), Proseries high rate [/Pattern /DeviceRGB] These levels are low enough that it normally will not be tasted. If you see any damage, replace your flow switch. Your salt level is between 2500-2600 parts per million (ppm). If the water temperature reads 215 degrees F, the cell temperature sensor is shorted and the cell needs to be replaced. Possible Remedies F}.s ? Lets dig a little deeper. You need to be really sure about the actual salinity reading. The arrow should point in the same direction as the water flow. For the best experience on our site, be sure to turn on Javascript in your browser. The 88-1 is not listed in any guides. If you are recalibrating but the system is still not working, Id check that you have the correct cell type selected on the diagnostics page. Ship Weight (lbs) : 24.10 I have tried to recalibrate, and keep getting the same thing. w !1AQaq"2B #3Rbr If the circuitry checks out, I would do the following checks, I pulled from our article: Troubleshooting Your Hayward Aqua Rite System, The NO FLOW LED stays ON when there is a flow switch problem. Not the 12VAC that it says should be there. Direct replacements for older Blue Essence salt chlorine generators, made by other brands. The following options are direct replacements if you have a Blue Essence model. Verify if your flow switch was installed correctly. Aquarite is not powering up at all. Troubleshooting and diagnosing their problems. I replaced the 5+ year old salt generating cell on the advice of my local pool supply store. We were away and the pool water level dropped below the input line and skimmer. 80 Review (s) Answered Questions. /ca 1.0 Tried recalibration and no change. Any suggestions? We can help you match the settings of your old system, or show you what youd need to oversize your system to guarantee the best salt pool experience. 0 Me gustan, Iniciada por Antonella Mitzi en Tecnologas de Informacin y Comunicacin el viernes. /SM 0.02 Are you sure it isnt the t-15 we show in the article? My PCB is a rev 1.4 BTW and I just replaced the thermistor as it was reading 0 and not generating. These levels are low enough that it normally will not be tasted. /Length 7 0 R What does it mean if the checks salt light is flashing but not the inspect cell? To Become a Customer please, Skip to the beginning of the images gallery, HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35. stream After the click, immediately push the diagnostic button 5 times to begin the recalibration stage. 0 Respuestas Step 2: Did you properly install your switch? If you program an incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. It always stays at 1600. Purchased and installed a new Hayward Goldline T-Cell 15 on my own two weeks ago its no longer working. After connecting the device, the flow led flashes for one minute and turns off. For the best experience on our site, be sure to turn on Javascript in your browser. Please consider. Lights still on. Turned the power on and the check salt & the Inspect Cell light are on, while the display panel is showing S lo. The instant salinity in both polarities should be about the same (+/- about 200 ppm). Hi Jason. This integrated solution automatically senses chlorine and pH levels and dispenses a self-renewing supply of pure chlorine while controlling pH. (HAY-45-0020), BLUE-ESSENCE-20 20K GAL SALT CHLORINATION SYSTEM, Product # : The IntelliChlor Salt Chlorinator power center must be installed more than 8 ft. (2.44 m) from the pool edges. Features integrated brine tank. Once it finishes calibrating, cycle the main switch from AUTO to SUPER CHLORINATE and back to AUTO. Finding the right option for your budget means happy swimming all around. Enviar un regalo, Anayansi Lpez de la Cruz Tweet During the last 6 months, there were chlorine generating problems. Have you checked the cells voltage, amperage, or done anything other troubleshooting? We have more than 13 years of experience in the production of billiards equipment, providing you with the most innovative technologies on the . It could also be the cell needs to be cleaned or replaced. stream Today I found it with no display and no light. w !1AQaq"2B #3Rbr Any idea what is going on? xFP%rzbTVv?/ON|"v#?)G 2m49bO~J6\`8N:PT%Tz R|-59I2?X$.234{,*Jsu x=)]sQ&y`v !QC}v/9I If the voltage between the orange and black is not 12VAC, you need to replace the rectifier or the board. Does a Goldline T-Cell-15 work as a replacement for Blue Essence 20 SWG, Weirdness: Blue-Essence-20 with BEX-CELL-20, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. The No Flow light is an indication that there is something funny going on with the flow inyour piping or the flow switch itself. Verify if your flow switch was installed correctly. Pool Care Basics How To Clean A Salt Cell In this Pool Care Basics, we show you how to clean calcium build-up in your salt cell using muriatic acid. Low salt and check cell lights are on constantly even though a test of the water indicates that the salt level is within the normal range. Salt Generators, UOM ( Default ) : /Producer ( Q t 4 . The other rectifier is rated as 18-33 VDC. Please contact me at mbrad39972@hotmail.com. You may want to take the opportunity to compare the specs and value of newer technology. 3jFEOUqPG=Go])F'.NF92l~g)ok89? (Yes, literally now.). Seeing as this is a salt chlorine generator, one of the most frequent error codes you will see will have to do with your salt levels or the cell where the salt is produced. phone & online customer support. 3 0 obj The arrows at the top of the hex nut should pointin the direction of the water flow. Part Number Description Warranty BLUE-ESSENCE-35 Salt Chlorinator for IG pools up to 35,000 gallons 2 year limited warranty Hi, we just installed a new AquaRite unit and it has been running for 48 hrs The salt level is 3100 ppm (pool store also confirmed and tested the water, no issues detected with the water). 1 2 . I replaced the o-ring and it still leaks out the same spot. Verify if the control is set to the correct turbo cell, How to Read and Adjust the Hayward Aqua Rite SCG Operational Values, Troubleshooting Your Hayward Aqua Rite System, Independently verify the salt levels in your swimming pool. It ran perfectly well with the previous SCG. I just cleaned the cell and keep getting a Cold code. The BLSC30 salt chlorine generator is certified by the Electrical Testing Laboratories (ETL) and produce Sanitized water that won't occur itchy skin, red eyes or hair problems. ltima respuesta de Juan Carlos Castro Baos el jueves. Direct replacements for older Blue Essence salt cells, made by other brands. ltima respuesta de Tommie Marshall ayer. /Type /XObject HAY-45-0020, Mfg : None of the indicating lights are on. Well, the good news is you are at the right spot and youre definitely not alone. 0 Respuestas If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. At this moment chlorine is still being produced, however your salt levels are dwindling. Hello, my salt generator seems to be always be producing at 100% no matter what my output dial is set at. Step 4: Verify your pumps pressure. Press and hold the diagnostic button for 3 to 5 seconds. The display doesnt turn on when the power is on, but it turns on briefly whenever the power is switched off. The LCD display will read HI. DiscountSaltPool.com is America's largest specialty provider of saltwater swimming pool equipment. I am having the same issue but my cell is only 4 months old, I am showing that I have no power to my T-cell. I would try a couple of turns of Teflon tape on the threads to create a better seal. System is not working. Also, make sure you plug in the cell all the way. Easily produce chlorine-based disinfectant on site with the De Nora MIOX 2 . Any ideas how to address this? But where are those codes and explanations usually? Manufactured by Goldline controls, the Blue Essence can chlorinate pools up to 20,000k gallons. get calls from people having problems where their Hayward Aqua Rite Salt Chlorator system reads a different level of salt than manual testing. It tells you the source of the issue. Inspect and clean your cell. I unplugged the cell cable, reconnected it, and the generator is now working properly. How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. You may want to take a toothbrush to it to clean off any residual scale. Drained the pool 16" to dilute the salt to 3300 ppm. Replumb your flow switch if it does not meet the distance requirements. View Hayward replacements for Blue Essence . /Subtype /Image This guide describes the Display Readings on a Hayward Aqua Rite Salt Chlorine Generator (SCG) and links you to a series of guides that tell you have to adjust or recalibrate some of these values including: Average Salt Level; Units of Measure, Cell Size, and Inspect Cell . Or are you taking a voltmeter to the output? Step 1: With your pump running, double-check the positions of your valves. I checked my cell, it was clean but I decided to replace it since it was 6 years old. 0ln~-Wz"2L?7=?6$3HGSw{ojCNF z w I r@4i 6yySw/N :W#yp@9N)Hede{,2i ,'xv]R# gu42H8R4?Ux~eTk?xgOAw2+HOt NI9~G71pPzhG9upm`x|9A_ip2sp]Ad2.~c If8;r:u_]?6'vZVfP11=YHVzg>v H+ ^9x}@? wSKL"\:N*.CDSB?S5M=/9wd]10)=Cw2 Salt level fine 3200. Wait 5 seconds before pressing the diagnostic button 5 times, and do it slowly. goJ|2OQ+*GqjEk[ W'= f(sqM,:sil|=us]>u T2>9'i.Z~*>rf:zP=N_M p %PDF-1.4 Thank you. >> I have a t-15 cell. How did it end up? Display seems to be reading correctly and shows the cell is not generating. There is a water temp sensor in the cell. All four lights on panel are lit. Should I have it checked or is this normal? ;X sM s69M \KUJ3II+d; VPpGNz =R^vC_^i$ojcS8 #%} ~e9qBuCOn>f@#JS{hPf( y:=k|K:{~PoKk _qybLrOJCs The 500 operation hour countdown timer expires. Looking for pool parts? 18.00x14.00x8.50. We typically recommend oversizing to prolong the life of your salt water generation system and provide better, more consistent sanitation and comfort. step of a long & overpriced distribution chain. Once it finishes calibrating, cycle the Main Switch from AUTO to SUPER CHLORINATE and back to AUTO. This is more of an indicator light than anything else. Step 1: Check your system to confirm that you have programmed the correct cell size. >> At no time does the power led turn on. That would be important as it would confirm there actually is a problem. 7) Availability: In Stock. The cell is new. What happens when you switch the output to super-chlorinate? If the amps show a reading that isnt within range, then you should replace your Turbo Cell. Talk to our US-based staff of friendly swimming $4%&'()*56789:CDEFGHIJSTUVWXYZcdefghijstuvwxyz ? Did you figure this out. Copyright 2020 INYOpools All rights reserved. 5 EDGE SYSTEM OVERVIEW The advanced compact EDGE salt system utilizes three main components for operation: Complete System Includes: Sensor Control Module: This component supplies power to the cell and allows you to customize the system's operation in order to meet your pool's unique needs. `X >rII89Jv%;_9f=n%zLS p|)"]g Y;NycR"WI>y{X=6$ziE- {O^M4 #8<7tCB2@{Njni~?/ >Uzq>v 3:zsUTe A?N*bRl3Nnkk?%>R?Oe>|% *ATnO0wgw,9 iO8SjO,/C x>||d0 s1%A}skYg6#RN|uO9/; 9sOPA>( You Save: $106.00(8%) $1,189.00. The standard AquaRite replacement main pcb is the GLX-PCB-RITE. /Filter /DCTDecode The operation requires a low concentration of salt (sodium chloride) in Manual for blue essence 20. If at any point you do not feel comfortable or simply just dont know what to do, definitely give us a call. Our expertise in the pool equipment market can help you truly find the best price for the system that has higher specs and works for you. If you are interested in upgrading from your old Blue Essence system to another, newer brand, our experts are here to help. If so, it will always read 100%. Pool gallon size ratings are maximum limits with chlorine generator equipment running at full capacity under ideal conditions & pool use. It was installed only about a year and a half ago. 20amp fuse is not blown. My Aqua Rite is displaying a code HoE. However, when I turn on the pump/generator power, I expected only the No Flow lamp to be lit. Ive done the reset and it still showing 4300. /Type /XObject The board is spelling HOt to denote the water temperature is reading above 140 degrees Fahrenheit. Slide your main switch to the AUTO position. - Excessive scaling on cell. # :LzJ,bMO3}On6`f2x3 I"%Qiv93a cOAOIp}]"a It wont stop leaking. The Salt Water Chlorine Generator Troubleshooting Guide will help you diagnose any problems and find the quick fix to get your system back on track! Lets explore the different Hayward Aqua Rite error codes, what they mean, and how you can get rid of them. Mine just did the same. You Save: $200.00(31%) Aftermarket Replacement Salt Cell for the Hayward Aquarite 25k gallon salt chlorine generator. I tested the breaker and the wires coming attached to the board and it's good. Matt, Its possible that the wrong cell size is selected in the diagnostics. If it is still making chlorine and no real faults are flashing on the control, I wouldnt be too worried about it. Called tech support said the main PCB needs replacement . Anyone have this issue or have any recommendations? the termistor was blown. The Inspect Cell LED (only) flashes or stays on when: The Check Salt & Inspect Cell LEDs flash together when: The Check Salt & Inspect Cell LEDs will stay ON when: Step 1: Check your system to confirm that you have programmed the correct cell size. The display does a lower case t and not the uppercase which is a little easier to distinguish. Its new cell T-15 .Checked cell looks clean inside. If you have an older salt chlorinator sold under Blue Essence branding, you'll want to now look at newer Hayward Aqua Rite model systems and replacement cells, which are direct replacements. 5) How to Read and Adjust the Hayward Aqua Rite SCG Operational Values, what are error codes 88-1 and R 8.1? /ColorSpace /DeviceRGB 0 Me gustan, Abimael De La Cruz Have more questions about Blue Essence systems or newer, more efficient alternatives? If your cell looks like 4A, continue to Step 4. (Your flow switch requires a minimum flow rate of 11 GPMs to stay consistently closed. Enviar un regalo, ANA STELLA MENDOZA PINILLA Upgrade to next larger size for $20 /Width 625 Same lights and error message are showing. Check the flow switch for damaged or cut wires. What are the most recent Total Chlorine and Free Chlorine test results? Reset the average salt level on startup and whenever you replace your cell. just replaced t15 on a rev 1.45 aqua rite and the default salt reading now is 4. A new cell a few years ago too. All Rights Reserved. endobj Amazon.com Hayward GLX-PCB-RITE Replacement Main PCB Were pool owners too, and we want to help people discover the benefits of new pool equipment technology so they can spend less time on pool maintenance, and more time enjoying their pool. The early revisions dont work with the TCELL5 or TCELL9. Check voltage coming out of transformer, it should be 24v. The only Aquarite value that matches that format is the Program Code but it should read AL-0. Quantity. %&'()*456789:CDEFGHIJSTUVWXYZcdefghijstuvwxyz 0 Me gustan, Iniciada por Juan Carlos Castro Baos en Capacitacin y Actualizacin Docente. High Salt/Amps/Minerals the Aqua Rite Pro will stop generating chlorine under certain high salt conditions in order to protect the internal electronics from damage. 5) 88?\cr'VO0'iB;3O I3=3HYYb09qU!99i+0qI=E). sSAA3w?~M:%%A]4R, ,zF x$Ov`wmy#o2 ' B>Sb@$K_}G>jEPNA'bv__9d=x7>J19;6*?][|3jVbIJ=8JcAn%%{"iF g mWl1 SRV#w?w9uhdGW smio4>BH=/k~DQ y endobj What was the solution? *. Step 3: Double check the wires on the flow switch for damage. When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. 7) My salt cell does not have a T-? The operation requires a low concentration of salt (sodium chloride) in the pool water. otherwise all else seems to read ok. Id check the cell number just to confirm it is the TCELL15. Por favor verifica la configuracion de tu navegador o contacta a el administrador de tu sistema. *The power/generating indicators are not illuminated at all. I replaced the display and the same problem occurs. Thanks for the schema!! Flow and temp fine. I have replaced the Aqua Rite printed circuit board and the T-Cell-9. /BitsPerComponent 8 More than likely, this temperature reading is not correct. You must log in or register to reply here. Newer technology also typically comes with less hassle and more efficient energy and time management. If you have an older salt chlorinator sold under Blue Essence branding, you'll want to now look at newer Hayward Aqua Rite model systems and replacement cells, which are direct replacements. *Important Specification, System Sizing, & Warranty Information: All specifications are based on Manufacturer published data as of January 2022. Chemical level fine. pool experts. Refer to pages 37-38 for troubleshooting/clearing the HOt code: AquaRite Troubleshooting Manual. /CA 1.0 Compatible plumbing replacement for: Hayward Goldline Aqua Rite, SwimPure Plus, AquaRite 900 Series, SwimPure Extreme, Mineral Springs, NatureSoft, AquaPlus, LeverEdge Guardian, Blue Essence, H40 systems and more. Facebook, Participar en RedDOLAC - Red de Docentes de Amrica Latina y del Caribe -, Bienvenido aRedDOLAC - Red de Docentes de Amrica Latina y del Caribe -, Anuncie sus Congresos o servicios Educativos en RedDOLAC, Iniciada por Iruma Alfonso Gonzlez en Tecnologas de Informacin y Comunicacin ayer. 24.10, Shipping Dimensions : $449.00. Id call the install tech for troubleshooting. Im trying to recalibrate my system but it starts at 4000 and slowly drops to 3700 and just jumps out of calibration sequence. I dont want to change both.Even the PCB is new bought bought in February 2018. from amazon ware house. Dont know how to fix this. << /Producer ( Q t 4 . This is a self-reply for others in the future.. 4 0 obj Still, one thing I do commend Hayward for is their simplistic error code guide. Even the power light is not on. Part Number: CIR-GEN9-RC. Eventually, it read check salt and check cell. Order online SALE: 0 Me gustan, Iniciada por Antonella Mitzi en Tecnologas de Informacin y Comunicacin el sbado. Page 4: Introduction 8 AWG US/ 6 AWG Canada. I have had an error code all summer but I cant find out anywhere what it means. Give us a call and learn about all of your options! The generator came on normally after the No Flow delay and is generating chlorine now. Safe and easy to useno dangerous chemicals to handle. 1 2 . Blue Essence chlorine generator and salt cells models are replaced with Hayward You may want to take the opportunity to compare the specs and value of The Aqua Rite is an automatic chlorine generation system for pool or spa sanitation. Its 89. Although I won't get into too many details on how great the product is, you can read our customer reviews to get unfiltered opinions about it. There should be at least 12 of straight pipe before the switch. Add to Cart. If the incorrect cell is chosen the salt level, amperage, and voltage will not be correct and the system will turn the chlorinator off. The Generating Light is flashing, while the Check Salt & Inspect lights are one. If this unit is new, you may also want to try contacting the manufacturer to determine if the unit is defective. << 1 0 obj If you program the incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. There isnt a break-in period for these units. When I quickly switch the power on-off-on, the display finally turns on and the no flow indiciator is still illuminated. . Salt chlorine generators are great products. The equipment you choose for your saltwater pool can truly shape your pool enjoyment experience. The High Salt light is exactly what it says There is literally a higher recommended amount of salt in your pool. BLUE ESSENCE-20 Be the first to review this product Description & Features Features Economical and eco-friendly UV and Ozone advanced water treatment system offers the ultimate in water quality and purity, eliminating 99.9% of chlorine-resistant microorganisms while reducing overall chlorine use by 50% or more It only says Blue Essence salt Cell on the cell and 20,000 gallon pool. Hi I have a Hayward extended life Turbocell 940-W with Hayward Goldline Pro Logic, displaying voltage and amp, but not producing chlorine or very little (not like normal). Obsolete : This can be used to identify and diagnose a number of issues, such as system error codes, check cell light (lit solid), check cell light (flashing), water flow, low salt, reprogramming the system for a new cell, and addressing production concerns. Thank you. Thanks. C*sz1]F?)! This spring I replace my control board. The control is set for the wrong turbo cell type. A flashing LED indicates a 15-60 second time delay period. Index -0.2 to 0.2 SOFTER, CLEANER WATER. Step 2: Did you properly install your switch? The LCD display will read COLD when the water temperature is below 50F. V#9Vw)QT'2=?LQ]zaKNn?_rG?NaFZ!&8$g~CPUwp 9=3>%1q z!.Y2l`nF*P pdN3Al}@Lwmk} 9hV} Fq`0NCArX>Op7FE& :qNy\8=8O R9@Bm\r'qB@mAp8=3c 4A!P0z{wi ``?$ ;pO^ INTELLICHLOR Electronic Chlorine Generator Installation Guide 3 Install the Power Center at eye level as close to the IntelliChlor Salt Chlorinator pump and filtration as possible. We have a Hayward Aqua Plus system. Thanks. What are the amp and volt readings for the new cell? If the incorrect cell is chosen the salt level, amperage, and voltage will not be correct and the system will turn the chlorinator off. My cell is only about 6 month old and I just cleaned it last week. When both these lights flash together, itmeans your salt level is between 2500 ppm and2600 ppm. Hayward Goldline AquaTrol Salt Chlorine Generator AQ-TROL-RJ. /BitsPerComponent 8 While sometimes you may expect that you need to pay more to get higher quality, we at DSP know that this isnt always the case when it comes to your pool system. $z>99z 1+l LaYr?4w(x{n mUPNrx\pzu0M YRYp Please strictly follow the manual for your own safety and operation of the salt chlorinator. /ca 1.0 Your email address will not be published. No flow, check salt, high salt, inspect cell. Enviar un regalo, Ana Isabel Tejada M BLUE-ESSENCE-20 20K GAL SALT CHLORINATION SYSTEM (HAY-45-0020) Product # : HAY-45-0020 Mfg : HAYWARD POOL PRODUCTS INC Mfg # : BLUE-ESSENCE-20 (FLORIDA ONLY) Department : FEEDERS | CHLORINATORS | SANTIZERS Product Line : Salt Generators UOM ( Default ) : EA Obsolete : This product is not obsolete. endobj All components of the Aqua Rite System are showing good readings and appears to be all set correctly. How do I clear the code Hot I have a new cell and its set to the correct cell settings. =j Q\:PE.I!r?^+wQr?$s}{Ny-[1p)$NF>es\=$2gp8PW_.eci!gqd>Ua 21?.60yU$c>u After every summer it is cleaned with the special cell solution. Blue essence salt chlorine generator owner's manual, RedDOLAC - Red de Docentes de Amrica Latina y del Caribe -, Aluminium composite panel installation methods pdf, Through the bible in felt teacher's manual pdf, Tramite su constancia de miembro activo de RedDOLAC, Tecnologas de Informacin y Comunicacin, Cmo elegir un alimento para mascotas de alta calidad, Compra uno de los modelos de paneles solares ms eficientes, La Constitucin colombiana - Un reto para la comprensin compleja, Nuevo Nmero de la Revista Debate Jurdico Ecuador. Any new postings here are unlikely to be seen or responded to by other members. The High Salt light will stay on for several reasons including: cell amperage is above the maximum limit, the control is set to the wrong turbo cell, or you simply have too much salt in your pool.
Focus Sleep Conference 2022,
Ohio License Plate Renewal Grace Period 2022,
Articles B